Solutions for
- Drinkink water / Large Buildings
- Irrigation
- Public water network
- Industry
Standard setting
- Aqua-4D® 360E Pro for max. 360 L/min or 21,6 m3/h incl. 1 Command 360E Pro + 1 Tube 360E
- Aqua-4D® 720E Pro for max. 720 L/min or 43.2 m3/h incl. 1 Command 360E Pro + 2 Tubes 360E
- Aqua-4D® 1080E Pro for max. 1080 L/min or 64.8 m3/h incl. 1 Command 360E Pro + 3 Tubes 360E
- Aqua-4D® 1440E Pro for max. 1440 L/min or 86.4 m3/h incl. 1 Command 360E Pro + 4 Tubes 360E + 1 Y360E
- Aqua-4D® 1800E Pro for max. 1800 L/min or 108 m3/h incl. 1 Command 360E Pro + 5 Tubes 360E + 2 Y360E
- Aqua-4D® 2160E Pro for max. 2160 L/min or 129.6 m3/h incl. 1 Command 360E Pro + 6 Tubes 360E + 3 Y360E
Tube 360E
Assembled directly onto the pipes, the Tube 360E is used to transmit electromagnetic signals (EM) into the water using its 2 solenoids.
Maximum flow rate: 360 L/min (21.6 m3/h).
Technical Data
Mechanical construction
- Length: 804 mm
- Max. diameter: 105 mm
- Size rating: 2" (DN 50)
- Weight: 8.7 kg
- Connection wire length: 280 cm
- Connector: Binder Series 423, 5 poles, male
- Maximum flow rate: 360 L/min (21.6 m3/h)
- Pressure rating: PN25 (SDR 9)
Ambient conditions
- IP 65
- Ambient temperature: 0 ... 60 [°C]
- Storage temperature: -25 ... 70 [°C]
Materials and accreditations for Tube 360E
Material: PVC-C, TC-Quickpipe, Thermoconcept GmbH & Co
Accreditations for drinking water
- SSIGE/SVGW (Switzerland)
- DVGW (Germany)
- OWG (Austria)
- ACS (France)
Command 360E Pro
Control unit that can control up to 6 Tubes 360E (Flow rate up to 2160 l/min, 129.6 m3/h)
Alarm output on a relay
Synchronisation of EM signals between several electronic devices (up to 32)
Possibility to set EM signals for specific applications
CE certification
Technical Data
Mechanical construction
- Dimensions without support feet: L x w x d: 240 x 180 x 120 mm
- Dimensions, including support feet: L x w x d: 260 x 180 x 125 mm
- Weight: 2.3 kg
- Control unit material: ABS PC
- Front material: polycarbonate
- Power cord: 2.9 meters length, output on cable gland, termination with striped wires (without plug)
- Tube connectors: Binder Series 423, 5 poles, female
- Relay connector: Binder Series 423, 3 poles, male
- Synchronisation Connector: Binder Series 423, 4 poles, mal
Power supply
- Voltage: 200 ... 240 V AC, 47 ... 63 Hz
- Power consumption: max. 50 VA
Tube power supply
- Courant max : 2 A
- Tension max : 20 V RMS
Alarm output
- Contacts without potential
- Max. permitted current: 3 A
- Max. permitted voltage: 230 V AC
Synchronisation output
- Max. current: 25 mA
- Nominal voltage: 7 ... 12 V DC
Ambient conditions
- IP 65
- Ambient temperature: 0 ... 40 [°C]
- Storage temperature: -25 ... 65 [°C]
- Electromagnetic compatibility: Emissivity and immunity in accordance with IEC 61000-6-1 and IEC 61000-6-3
- Protection from overvoltage: in accordance with IEC 61000-4-5
- Relative humidity: 0 ... 95 %, without condensation
Programming
- Firmware update
- Setting EM signals